Master the AI-Optic Vision Screener with this Operating Video!
Table of Contents
- Introduction
- Unboxing and Contents
- Product Appearance
- Charging and Power Modes
- Power On and Off
- Lock Screen Settings
- Wi-Fi Configuration
- Settings
- Preparing for Examination
- Starting the Examination
- Saving and Deleting Data
- Data Export
- Troubleshooting
🔍 Introduction
Welcome to the world of AI Optic Vision Screener! In this guide, we will provide you with all the information you need to get started with your brand new device. From unboxing and setting it up to performing accurate visual evaluations, we've got you covered. So let's dive in and explore the functionalities and features of the AI Optic Vision Screener.
📦 Unboxing and Contents
Before we begin, let's quickly go through the unboxing process and take a look at the contents of the Package. Once you receive your AI Optic Vision Screener, ensure that the outer packaging is intact and free from any damage that might have occurred during shipping. Carefully open the packaging and check the contents. Inside, you will find:
- AI Optic Vision Screener device
- Type C power cable
- Power adapter
- Tripod
- Screen cleaning cloth
- User manual
Make sure all the items are included and in good condition. If you Notice any discrepancies or damages, contact our Customer Service immediately.
👁️ Product Appearance
The AI Optic Vision Screener device features a sleek and modern design. It is equipped with a 7-inch touchscreen display that allows you to interact with the device effortlessly. To navigate through the various functions and options, simply touch the corresponding icon on the home screen. On the side of the device, you will find a USB power port. Please note that this port is solely for charging purposes and should not be used for data transmission. To avoid any potential damage, refrain from plugging in external devices into the USB port.
🔋 Charging and Power Modes
The AI Optic Vision Screener supports two power modes: battery mode and wired mode. In battery mode, the device operates without being plugged into a power source. In wired mode, the device is connected to the power source via the power cable. Before using the device for the first time, it is essential to charge the battery. To charge the battery, plug the Type C connector into the USB port of the device and the Type A connector into the USB port of a power source. A charging battery icon will appear on the screen, indicating that the device is charging. It usually takes approximately two hours to fully charge the battery, and once fully charged, the device can run for about two hours on battery power. When the battery level drops below 20%, the battery icon on the screen turns red. It is possible to use the device while it is being charged.
⚡ Power On and Off
To power on the AI Optic Vision Screener, simply press and hold the power button for two seconds. To turn off the device, there are two options:
- Tap the power off icon in the navigation bar.
- Press and hold the power button for four seconds, and when the dialog box appears, tap "Yes" to confirm.
In case the device becomes unresponsive, press and hold the power button for six seconds to force a shutdown.
🔒 Lock Screen Settings
The AI Optic Vision Screener features an automatic lock screen function. If the device remains unused for five minutes, it automatically locks the screen. To wake up the device, simply tap the screen. However, if the device remains idle for 10 minutes, it will power off automatically. To customize the lock screen settings, go to the "Settings" option on the home screen and select "Screen Timeout." Here, you can choose your desired lock screen timeout duration.
📶 Wi-Fi Configuration
When using the AI Optic Vision Screener for the first time, a Wi-Fi configuration screen will pop up automatically. Select your desired Wi-Fi network, enter the password, and click "Connect" to complete the connection. Once you save the Wi-Fi network configuration, the device will automatically recognize the signal and connect to the network. To change the Wi-Fi network, go to "Settings" on the home screen, select "Wi-Fi," choose another network, enter the password, and connect to the new network.
⚙️ Settings
To personalize your experience with the AI Optic Vision Screener, it is important to set up your preferred user preferences. Tap on "Settings" on the home screen, and you will find the following options:
- Language: Select your preferred language.
- Time Zone: The device's time is automatically adjusted when connected to the internet. However, you can manually set the time zone by selecting your country's time zone.
- WLAN: Connect to a Wi-Fi network.
- Referral Criteria: Choose from Arnold, Mata Silbert, or Arthur II referral criteria based on your location and requirements.
- Factory Settings: Restore the device to its original system settings.
- System Update: Check for system updates and choose to update if a newer version is available.
- Machine ID: View the unique code assigned to your device.
- Screen Timeout: Customize the duration before the lock screen is activated.
Make sure to adjust these settings according to your preferences for a seamless experience with the AI Optic Vision Screener.
🔦 Preparing for Examination
Before conducting any visual evaluations, it is crucial to prepare the examination environment properly. The AI Optic Vision Screener uses carefully designed infrared light that is safe for human eyes. To ensure accurate measurements, follow these steps:
- Perform the examination indoors away from direct sunlight. Sunlight can interfere with the precision of the readings, so close the curtains and blinds.
- Use the included tripod stabilizing device to improve stability and accuracy during the examination.
By preparing the examination environment diligently, you can ensure reliable and precise results.
📸 Starting the Examination
To start the examination, begin by entering the name, gender, and date of birth of the subject. Once done, tap the camera icon to proceed with the examination. It is essential to adjust the brightness for optimal results. Check the brightness value displayed on the screen and ensure it is less than five. If it exceeds five, the flash function cannot be turned on, and you need to reduce the surrounding environment's brightness. On the other HAND, if the value is less than five, you can turn on the flash function. Once the brightness is appropriately adjusted, proceed to the measurement step. The examination should be conducted in a quiet environment with minimal distractions. For children, ensure they are calm and able to remain still during the examination. Adjust the examination distance by placing the device at eye level of the subject or fixing it on a tripod about three to four feet away from their face. The position of both the device and the subject should be adjusted until a clear corneal reflection point is obtained. Once everything is set, the subject should look directly into the device during the examination, sitting upright with their body facing the camera. It is recommended to remove glasses or contact lenses before starting the examination to ensure accurate results.
💾 Saving and Deleting Data
After each examination, the results are automatically saved. To delete a result, go to the "Examination Records" on the home screen, enter the name of the subject, find the corresponding data, and delete it. This allows for efficient data management and organization.
📤 Data Export
If you need to export the examination results, you can use the data export feature. After completing the examination, click the export button, enter the email address to receive the file, and submit it. You will then receive an email containing the Relevant data file.
🛠️ Troubleshooting
In case you encounter any issues with your AI Optic Vision Screener, here are some common troubleshooting steps:
- Device won't turn on: Check if the power supply is properly plugged in and press the power button to turn on the device.
- Device screen locks suddenly: The screen automatically locks after a period of idleness. Simply touch the screen to wake it up. If it doesn't respond, power on the device again.
- Measurement failure: Clear images are essential for successful measurements. Ensure that the device is at an appropriate distance from the subject, adjust the position of both, and make sure the subject's eyes are clearly visible on the screen. If the subject is wearing glasses, ask them to remove them before conducting the examination.
- No pupils are found: If the subject has certain eye conditions or if their pupils are blocked, the examination may not be successful. Proceed with the referral process in such cases.
- Brightness value is too great: Excessive brightness can affect the examination results. Close curtains or blinds to block external sunlight. Incandescent lights may also impact the examination, so it is recommended to use fluorescent or LED lights. If the brightness value is less than five, you can turn on the flash function.
- Measurement not completed: Remind the subject to keep their eyes open and avoid frequent blinking during the examination. Also, ensure a stable Wi-Fi connection for uninterrupted measurements.
- Eyes closed or blocked: If the subject closes their eyes or their eyes are obstructed, the examination will fail. Remind the subject to keep their eyes open and remove any obstructions.
By following these troubleshooting tips, you can resolve common issues and ensure a smooth experience with your AI Optic Vision Screener.
⭐ Highlights:
- Unboxing and checking the contents of the AI Optic Vision Screener package.
- Understanding the product appearance and its touchscreen controls.
- Charging the device and switching between battery and wired modes.
- Powering on and off the device and adjusting lock screen settings.
- Configuring Wi-Fi and personalizing settings according to preferences.
- Ensuring the examination environment is suitable for accurate measurements.
- Starting the examination and adjusting brightness for optimal results.
- Saving and deleting examination data for efficient management.
- Exporting examination results for further analysis.
- Troubleshooting common issues encountered with the AI Optic Vision Screener.
📚 Resources:
FAQ
-
Q: Can the AI Optic Vision Screener be used outdoors?
- A: It is recommended to perform the examination indoors, away from direct sunlight, to ensure accurate readings.
-
Q: What is the importance of adjusting the brightness during the examination?
- A: Adjusting the brightness ensures clear images and proper functioning of the flash function if required.
-
Q: How long does it take to fully charge the battery?
- A: It takes approximately two hours to fully charge the battery, providing around two hours of usage on battery power.
-
Q: Can the AI Optic Vision Screener be used while it is being charged?
- A: Yes, the device can be used while it is being charged.
-
Q: Can the AI Optic Vision Screener measure the visual acuity of children?
- A: Yes, the device supports specialized referral criteria suitable for children's visual evaluations.