Master 810DX Skills with this Training Video
Table of Contents:
- Introduction to Accurate Pipe and Cable Locating
- Why Accurate Locating is Important
- Metro Tech 810 DX Line Locators: Features and Benefits
- Methods of Locating Buried Utilities
4.1 Active Locating
4.1.1 Conductive or Direct Connect Method
4.1.2 Inductive Coupling or Clamp Method
4.1.3 Inductive or Indirect Method
4.2 Passive Locating
- Metro Tech 810 DX Line Locator: Transmitter Features and Instructions
5.1 Battery Check and Replacement
5.2 Conductive or Direct Connect Method Instructions
5.3 Inductive Coupling or Clamp Method Instructions
5.4 Inductive or Indirect Method Instructions
- Metro Tech 810 DX Line Locator: Receiver Features and Instructions
6.1 Distance Sensitive Left/Right Guidance
6.2 Digital Signal Strength Display
6.3 Depth and Gain Adjustments
- Preparing for Pipe and Cable Locating
7.1 Safety Measures
7.2 Consulting Blueprints and As-Built Documentation
7.3 Orienting Yourself with Visual Points
- Step-by-Step Guide to Pipe and Cable Locating with Metro Tech 810 DX
8.1 Checking Transmitter and Receiver Batteries
8.2 Connecting and Grounding the Transmitter
8.3 Conductive or Direct Connect Method
8.4 Inductive Coupling or Clamp Method
8.5 Troubleshooting Ground and Resistance Issues
8.6 Using the Metro Tech 810 DX Receiver for Guidance
- Efficient and Accurate Pipe and Cable Locating Techniques
9.1 Utilizing the Line Resistance Check Feature
9.2 Understanding Field Strength Numbers
9.3 Adjusting Signal Strength with Clamp Size
- Conclusion
Article:
Introduction to Accurate Pipe and Cable Locating
Accurate pipe and cable locating is an essential aspect of safe excavation. Whenever there is a need to dig, it is crucial to have a clear understanding of the location of underground utilities such as Water, power, sewer, telephone, gas, fiber-optic, and cable TV lines. Accidentally digging into any of these lines can disrupt service to the public and result in serious injury to You or your crew members. In this program, we will explore how the Metro Tech 810 DX line locators can improve the efficiency and accuracy of your locates.
Why Accurate Locating is Important
Accurate pipe and cable locating is of utmost importance to prevent accidents and ensure the successful completion of excavation projects. By accurately locating underground utilities, you can avoid disruptions to essential services and minimize the risk of injury. With the help of Metro Tech 810 DX line locators, you can significantly enhance the accuracy of your locates, reducing the chances of hitting buried utilities and improving overall safety.
Metro Tech 810 DX Line Locators: Features and Benefits
The Metro Tech 810 DX line locators are sophisticated yet user-friendly electronic instruments designed to make pipe and cable locating easier and more efficient. These line locators employ the active locating method, which involves a transmitter and a receiver to accurately locate buried utilities. With features such as continuous Current output, output power levels, quality line resistance check, automatic battery check, and a rugged design, the Metro Tech 810 DX line locators are reliable tools that can streamline your locating process and save you valuable time in the field.
Methods of Locating Buried Utilities
There are two primary methods of locating buried utilities: active locating and passive locating. Active locating utilizes a transmitter and receiver to send and detect signals, while passive locating relies on identifying naturally occurring signals emitted by utilities.
Active Locating
Active locating is the standard method used to accurately locate buried utilities. It involves the use of a transmitter and receiver to send and detect signals. There are three methods of transmitting the signal onto the target conductor: conductive or direct connect method, inductive coupling or clamp method, and inductive or indirect method.
The conductive or direct connect method is the preferred active locating technique as it provides the strongest signal. It requires a direct connection between the transmitter and the metallic conductor. If direct connect is not possible, the inductive coupling method can be used by positioning a Metro clamp around the conductor to induce a signal onto it. The inductive or indirect method is employed only when the other two methods are not feasible, as it broadcasts a signal that is picked up by all conductors within range, making it less precise.
Passive Locating
Passive locating involves identifying naturally occurring signals emitted by buried utilities. This method relies on detecting electromagnetic signals, such as those emitted by power lines or radio frequency identification (RFID) tags attached to utilities. While passive locating can be effective, it is less precise than active locating and may require specialized equipment.
To ensure accuracy and efficiency in locating buried utilities, we will focus on the active locating methods using the Metro Tech 810 DX line locators.
Metro Tech 810 DX Line Locator: Transmitter Features and Instructions
The Metro Tech 810 DX transmitter is an active radio frequency utility line locator that incorporates various features to enhance your locating process. It features continuous current output, multiple output power levels, quality line resistance check, automatic continuous battery check, and an environmentally sealed design. The transmitter is available with replaceable or rechargeable batteries, providing flexibility for extended use.
Before starting your locate, ensure that the transmitter and receiver batteries are adequately charged. The transmitter's battery level can be checked by pressing the on/off button, which displays the battery level as a percentage. A fully charged battery will Show 100%, while all LEDs flashing indicate low battery power. It is essential to turn off the transmitter before plugging in the leads to avoid accidental shock.
When using the conductive or direct connect method, it is crucial to test for the presence of live current using a voltmeter before attaching the transmitter to any conductor. If electrical current is detected, disconnect the power source following appropriate safety procedures. If disconnecting the current is not possible, utilize the inductive clamp or inductive method to locate your target.
To ensure safety during the direct connect method, make sure the transmitter power is off before plugging in the direct connect cable. The Metro Tech 810 DX transmitter has high power output, and handling both leads with the power on can result in a shock hazard. Additionally, it is essential to ground the transmitter to provide a path for the current. If no existing ground is available, use the ground spike provided with the transmitter. The ground spike should be driven into the ground at a right angle to your target conductor, away from any other buried conductors.
After connecting the leads and grounding the transmitter, the next step is to establish a good metal-to-metal contact. The better the contact, the stronger the signal will be. Ensure that the ground wire does not lay across or too close to another buried conductor, as this may cause unwanted signals or difficulties in isolating your target.
Continued...